| Commit message (Collapse) | Author | Age | Files | Lines |
| |
|
|
|
|
|
|
| |
Fixups to a few test cases.
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
| |
|
|
|
|
|
|
|
|
|
|
| |
Local group membership Add/Remove working, however with
BUILTIN local system groups .NET doesn't appear to locate them as either
groups nor basic security Principals. Still needs work to fix the test
for nested groups. Ideally with some way to test for domain groups.
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
|
|
|
| |
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
|
|
|
| |
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Table names updated for Wix4 prefix.
Custom action names similarly updated.
Table names Wix4ComPlusUserInApplicationRole,
Wix4ComPlusGroupInApplicationRole and Wix4ComPlusApplicationRoleProperty
had to be shortened to fit within MSI 31 character table name limit.
Migrated from fixed GUID for RegistrationHelper to use CLSIDFromProgID in
an attempt to fix behaviour under .NET 4+ DLLs.
Added setting of Partition enable if a Partition is configured in authoring,
new Windows config has Partitions disabled by default, and they don't work
at all under Windows workstation (non-server) versions.
Added a new Runtime condition for `RequireWindowsServer` which will skip
execution of Runtime test on workstation/desktop OSes, since COM+ Partitions
only work correctly under Windows Server.
Quite a lot of basic typos fixed also.
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
|
|
|
|
|
|
|
| |
Contains no files etc to verify that Remove action can still occur without
other elements bringing in the RemoveFiles Standard Action
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
|
|
|
|
|
|
|
|
| |
Fix up lack of WIX CUSTOM_ACTION_DECORATION wrappers
Add new RuntimeTest skipper for Server Features / Optional Features.
Signed-off-by: Bevan Weiss <bevan.weiss@gmail.com>
|
|
|
|
| |
Fixes 8638
|
|
|
|
|
|
|
| |
The MSBuild Version property is well-known and can be set by standard
processes. That can cause problem in the tests where the version is explicitly
set to validate WiX behaviors. So, we've switched to using the TestVersion
property that will be specific for our testing purposes.
|
|
|
|
|
|
| |
folder
Fixes 8078
|
| |
|
| |
|
|
|
|
| |
Fixes https://github.com/wixtoolset/issues/issues/8036.
|
| |
|
|
|
|
| |
attributes
|
| |
|
| |
|
| |
|
| |
|
|
|
|
|
| |
Fixes https://github.com/wixtoolset/issues/issues/7377.
Requires fix for https://github.com/wixtoolset/issues/issues/7444.
|
|
|
|
|
|
|
|
|
|
| |
- Count args before creating message record.
- Document terminating NULL requirement.
- Add terminating NULL in MessageExit* macros.
- Enhance tests for problems encountered fixing this nightmare.
Fixes https://github.com/wixtoolset/issues/issues/7422.
Fixes https://github.com/wixtoolset/issues/issues/7444.
|
| |
|
|
|
|
| |
Fixes 5371
|
|
|